# Inne hypervisory i porównanie

oVirt, OLVM, XCP-ng i porównanie wszystkich mechanizmów HA.

# Inne hypervisory z HA: oVirt, Oracle Linux Virtualization Manager i XCP-ng

<span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#475569;color:#fff">🎚️ Poziom: średnio</span><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#0f766e;color:#fff">🧩 Dotyczy: oVirt 4.5.7, Oracle Linux Virtualization Manager 4.5 (hosty Oracle Linux 8 i 9), XCP-ng 8.3 <abbr title="Long Term Support: wersja z długim wsparciem poprawkami">LTS</abbr> z Xen Orchestra i <abbr title="magazyn hiperkonwergentny w XCP-ng: łączy lokalne dyski hostów w jeden współdzielony magazyn z replikacją przez LINSTOR i DRBD">XOSTOR</abbr>, VMware vSphere <abbr title="High Availability: wysoka dostępność, czyli działanie mimo awarii jednego elementu">HA</abbr> jako punkt odniesienia, klaster Hyper-V hv01 i hv02</span><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#7c3aed;color:#fff">⏱️ Czas: ~60 min</span>

*Zielona ma dziś jeden hypervisor, Hyper-V, a książka opisuje jego klaster i klaster Proxmox VE. Na tej stronie przeglądamy trzy inne rodziny: oVirt, jego komercyjną odmianę od Oracle (<abbr title="Oracle Linux Virtualization Manager: komercyjnie wspierana odmiana oVirt od Oracle, której hosty działają na Oracle Linux">OLVM</abbr>) i XCP-ng. Dla każdej mówimy, kim jest, w jakim stanie jest projekt w październiku 2026, jak działa jej wysoka dostępność i na jakie pułapki trafia administrator, a na końcu zestawiamy je z Hyper-V i Proxmox VE.*

<p class="callout warning">Nic z tej strony nie było uruchomione w Zielonej ani w naszym laboratorium. Opisujemy dokumentację producentów i projektów, a komendy z Fiszki tylko odczytują stan i podajemy je bez przykładowych wyników, bo nie mamy działającego środowiska, z którego moglibyśmy je zebrać. Stan projektów sprawdziliśmy 3 października 2026.</p>

<div id="bkmrk-%F0%9F%A7%AD-za%C5%81o%C5%BBenia-scenariu" style="border:1px solid rgba(14,116,144,.45);border-left:6px solid #0e7490;border-radius:10px;padding:12px 18px;margin:18px 0;background:rgba(14,116,144,.07)"><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#0e7490;color:#fff">🧭 ZAŁOŻENIA SCENARIUSZA</span>

Zielona nie ma dziś ani oVirt, ani XCP-ng: strona zestawia dokumentację producentów z naszym klastrem `hv01` i `hv02` (dwa hosty i świadek poza klastrem) w jednej serwerowni. Żadnego z opisanych układów nie uruchamialiśmy w laboratorium.

</div><details id="bkmrk-%F0%9F%94%A4-skr%C3%B3ty-u%C5%BCyte-na-te"><summary>🔤 Skróty użyte na tej stronie (28)</summary>

<table style="width:100%"><thead><tr><th style="width:18%">Skrót</th><th>Co znaczy</th></tr></thead><tbody><tr><td>**BMC**</td><td>Baseboard Management Controller: osobny malutki komputer na płycie serwera, który działa nawet przy wyłączonym serwerze i odczytuje m.in. temperatury czujników</td></tr><tr><td>**CHAP**</td><td>Challenge-Handshake Authentication Protocol: uwierzytelnianie hasłem przy połączeniach iSCSI; XCP-ng nie pozwala użyć takiego magazynu na heartbeat HA</td></tr><tr><td>**CI**</td><td>Continuous Integration: automatyczne budowanie i testowanie kodu po każdej zmianie; w ITIL także configuration item, czyli element konfiguracji: każdy składnik usługi zapisany w CMDB</td></tr><tr><td>**dom0**</td><td>domena sterująca w XCP-ng i Xen: specjalna maszyna na hoście, w której działają sterowniki i narzędzia zarządzania</td></tr><tr><td>**DRBD**</td><td>Distributed Replicated Block Device: replikowane urządzenie blokowe w jądrze Linuksa, w którym każdy zapis trafia na dwa węzły</td></tr><tr><td>**ESXi**</td><td>hypervisor firmy VMware instalowany na serwerze, na którym działają maszyny wirtualne zarządzane z vCenter</td></tr><tr><td>**GFS2**</td><td>Global File System 2: klastrowy system plików Linuksa, który kilka serwerów montuje naraz na tym samym dysku</td></tr><tr><td>**GiB**</td><td>gibibajt: 1024 MiB, czyli około 1,07 GB; tej jednostki używa dokumentacja MailCow przy wymaganiach pamięci</td></tr><tr><td>**HA**</td><td>High Availability: wysoka dostępność, czyli działanie mimo awarii jednego elementu</td></tr><tr><td>**ICMP**</td><td>Internet Control Message Protocol: protokół diagnostyczny sieci, którym działa między innymi ping</td></tr><tr><td>**iSCSI**</td><td>Internet Small Computer System Interface: sposób udostępniania dysku z macierzy po zwykłej sieci IP, tak że serwer widzi go jak własny dysk</td></tr><tr><td>**KVM**</td><td>Keyboard, Video, Mouse: konsola albo przełącznik, który daje jedną klawiaturę, ekran i mysz do wielu serwerów (w Linuksie KVM to też technika wirtualizacji)</td></tr><tr><td>**LINSTOR**</td><td>program do zarządzania replikowanymi woluminami DRBD na wielu serwerach, na którym stoi XOSTOR</td></tr><tr><td>**LTS**</td><td>Long Term Support: wersja z długim wsparciem poprawkami</td></tr><tr><td>**NFS**</td><td>Network File System: udostępnianie katalogów po sieci w świecie Linuksa</td></tr><tr><td>**OLVM**</td><td>Oracle Linux Virtualization Manager: komercyjnie wspierana odmiana oVirt od Oracle, której hosty działają na Oracle Linux</td></tr><tr><td>**POSIX**</td><td>Portable Operating System Interface: wspólny zestaw zasad, dzięki któremu polecenie działa tak samo na różnych Uniksach</td></tr><tr><td>**RAM**</td><td>Random Access Memory: pamięć operacyjna</td></tr><tr><td>**RHEL**</td><td>Red Hat Enterprise Linux: komercyjna dystrybucja Linuksa</td></tr><tr><td>**SMB**</td><td>Server Message Block: protokół udostępniania plików i drukarek w sieci Windows, na nim stoi zwykły udział sieciowy</td></tr><tr><td>**UDP**</td><td>User Datagram Protocol: szybki protokół sieciowy bez potwierdzeń</td></tr><tr><td>**UEK**</td><td>Unbreakable Enterprise Kernel: jądro Linuksa dostarczane przez Oracle w Oracle Linux, osobne od jądra z Red Hat</td></tr><tr><td>**VCF**</td><td>VMware Cloud Foundation: pakiet Broadcom, który łączy vSphere z magazynem, siecią i zarządzaniem w którym Broadcom sprzedaje dziś licencje vSphere</td></tr><tr><td>**VDSM**</td><td>Virtual Desktop and Server Manager: agent na każdym hoście KVM w oVirt i OLVM, który wykonuje polecenia silnika, takie jak uruchom maszynę albo podłącz magazyn</td></tr><tr><td>**VM**</td><td>Virtual Machine: maszyna wirtualna</td></tr><tr><td>**XAPI**</td><td>Xen API: interfejs, przez który narzędzia zarządzają hostami i maszynami w XCP-ng; w puli odpowiada na nim host master</td></tr><tr><td>**XOA**</td><td>Xen Orchestra Appliance: gotowa maszyna wirtualna z Xen Orchestra, z którą Vates sprzedaje wsparcie i dodatkowe funkcje</td></tr><tr><td>**XOSTOR**</td><td>magazyn hiperkonwergentny w XCP-ng: łączy lokalne dyski hostów w jeden współdzielony magazyn z replikacją przez LINSTOR i DRBD</td></tr></tbody></table>

</details>## Fiszka

Komendy wykonujemy w powłoce bash z uprawnieniami root (`sudo`), a te z `xe` na dowolnym hoście puli XCP-ng. Żadna z nich niczego nie zmienia. W Zielonej nie ma dziś ani oVirt, ani XCP-ng, więc tę Fiszkę traktujemy jako ściągę na dzień, w którym trafimy na taki system w innej firmie albo w laboratorium. Przy komendach opisujemy, na co patrzymy w wyniku, bo kształtu odpowiedzi nie znamy z własnego uruchomienia.

<div id="bkmrk-%F0%9F%9F%A2-tylko-odczyt-odczy" style="border:1px solid rgba(22,163,74,.35);border-left:6px solid #16a34a;border-radius:10px;padding:12px 18px 6px 18px;margin:20px 0;background:rgba(22,163,74,.06)"><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#16a34a;color:#fff">🟢 TYLKO ODCZYT</span>

### Odczyt stanu silnika oVirt na hoście: hosted-engine --vm-status

```bash
sudo hosted-engine --vm-status
```

Dotyczy układu z silnikiem w maszynie na hostach (self-hosted engine) w oVirt i OLVM. Polecenie wypisuje sekcję dla każdego hosta ze stanem silnika (pole `Engine status`), a Oracle pokazuje je w swoim opisie kopii zapasowej silnika z filtrowaniem po tym polu \[14\].

🔤 **OLVM** = Oracle Linux Virtualization Manager: komercyjnie wspierana odmiana oVirt od Oracle, której hosty działają na Oracle Linux · **hosted-engine** = silnik wbudowany: narzędzie oVirt i OLVM do wdrożenia silnika w maszynie na hostach, z opcją --vm-status, która pokazuje jego stan na każdym hoście

</div><div id="bkmrk-%F0%9F%9F%A2-tylko-odczyt-odczy-1" style="border:1px solid rgba(22,163,74,.35);border-left:6px solid #16a34a;border-radius:10px;padding:12px 18px 6px 18px;margin:20px 0;background:rgba(22,163,74,.06)"><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#16a34a;color:#fff">🟢 TYLKO ODCZYT</span>

### Odczyt puli XCP-ng i jej mastera: xe pool-list

```bash
xe pool-list params=name-label,master,ha-enabled
```

Pokazuje nazwę puli, identyfikator hosta, który jest masterem, i to, czy HA jest włączone. Parametr `ha-enabled` należy do parametrów puli opisanych w dokumentacji interfejsu wiersza poleceń \[18\], a samo `xe` to narzędzie, którym rozmawiamy z interfejsem <abbr title="Xen API: interfejs, przez który narzędzia zarządzają hostami i maszynami w XCP-ng; w puli odpowiada na nim host master">XAPI</abbr> puli.

🔤 **HA** = High Availability: wysoka dostępność, czyli działanie mimo awarii jednego elementu · **XAPI** = Xen API: interfejs, przez który narzędzia zarządzają hostami i maszynami w XCP-ng; w puli odpowiada na nim host master

</div><div id="bkmrk-%F0%9F%9F%A2-tylko-odczyt-odczy-2" style="border:1px solid rgba(22,163,74,.35);border-left:6px solid #16a34a;border-radius:10px;padding:12px 18px 6px 18px;margin:20px 0;background:rgba(22,163,74,.06)"><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#16a34a;color:#fff">🟢 TYLKO ODCZYT</span>

### Odczyt hostów puli XCP-ng: xe host-list

```bash
xe host-list params=name-label,address,enabled
```

Wypisuje hosty z adresem zarządzania i informacją, czy host przyjmuje nowe maszyny. Host z `enabled` ustawionym na `false` jest wyłączony z przyjmowania maszyn, na przykład po `xe host-disable` \[18\].

</div><div id="bkmrk-%F0%9F%9F%A2-tylko-odczyt-oblic" style="border:1px solid rgba(22,163,74,.35);border-left:6px solid #16a34a;border-radius:10px;padding:12px 18px 6px 18px;margin:20px 0;background:rgba(22,163,74,.06)"><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#16a34a;color:#fff">🟢 TYLKO ODCZYT</span>

### Obliczenie, ile awarii hostów pula zniesie: xe pool-ha-compute-max-host-failures-to-tolerate

```bash
xe pool-ha-compute-max-host-failures-to-tolerate
```

Polecenie tylko liczy: dokumentacja XCP-ng mówi, że wynik uwzględnia liczbę hostów i dostępną pamięć <abbr title="Random Access Memory: pamięć operacyjna">RAM</abbr> \[16\]. Wartość zapisaną w puli odczytujemy parametrem `ha-host-failures-to-tolerate` z `xe pool-param-list`.

🔤 **RAM** = Random Access Memory: pamięć operacyjna

</div><div id="bkmrk-%F0%9F%9F%A0-zmienia-system-odc" style="border:1px solid rgba(217,119,6,.35);border-left:6px solid #d97706;border-radius:10px;padding:12px 18px 6px 18px;margin:20px 0;background:rgba(217,119,6,.06)"><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#d97706;color:#fff">🟠 ZMIENIA SYSTEM</span>

### Odczyt priorytetów restartu maszyn w XCP-ng: xe vm-list

```bash
xe vm-list is-control-domain=false params=name-label,power-state,ha-restart-priority
```

Wypisuje maszyny z priorytetem restartu przy awarii hosta. Wartości `restart`, `best-effort` i `disabled` opisuje dokumentacja HA \[16\], a `is-control-domain=false` pomija maszynę sterującą hosta (<abbr title="domena sterująca w XCP-ng i Xen: specjalna maszyna na hoście, w której działają sterowniki i narzędzia zarządzania">dom0</abbr>).

🔤 **HA** = High Availability: wysoka dostępność, czyli działanie mimo awarii jednego elementu · **dom0** = domena sterująca w XCP-ng i Xen: specjalna maszyna na hoście, w której działają sterowniki i narzędzia zarządzania

</div><div id="bkmrk-%F0%9F%9F%A2-tylko-odczyt-odczy-3" style="border:1px solid rgba(22,163,74,.35);border-left:6px solid #16a34a;border-radius:10px;padding:12px 18px 6px 18px;margin:20px 0;background:rgba(22,163,74,.06)"><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#16a34a;color:#fff">🟢 TYLKO ODCZYT</span>

### Odczyt węzłów XOSTOR: linstor node list

```bash
linstor node list
```

Dotyczy tylko XCP-ng z XOSTOR. Pokazuje węzły z adresem i stanem połączenia, a kolejne polecenia z dokumentacji XOSTOR to `linstor resource list` i `linstor storage-pool list` \[17\].

🔤 **XOSTOR** = magazyn hiperkonwergentny w XCP-ng: łączy lokalne dyski hostów w jeden współdzielony magazyn z replikacją przez LINSTOR i DRBD · **linstor** = narzędzie wiersza poleceń LINSTOR: pokazuje węzły, zasoby i pule magazynu XOSTOR, na przykład linstor node list

</div>## Z życia wzięte

<div id="bkmrk-%F0%9F%93%96-z-%C5%BBycia-wzi%C4%98te%C5%9Arod" style="border-left:6px solid #b45309;border-radius:10px;padding:14px 18px;margin:18px 0;background:rgba(180,83,9,.07)"><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#b45309;color:#fff">📖 Z ŻYCIA WZIĘTE</span>

Środa, 11:15. Pan Zbigniew kładzie na biurku wydruk artykułu o zmianach cen i licencji u jednego z dużych dostawców wirtualizacji i pyta, czy `hv01` i `hv02` to jedyna droga. Ola odpowiada, że klaster Hyper-V zostaje, bo działa, ale dla porządku zrobią listę innych rozwiązań z drugim hostem. Tomek dopisuje na tablicy trzy nazwy, które słyszał na forach, i od razu pyta, czy któraś z nich żyje.

</div>Pytanie Tomka jest najważniejsze, bo wirtualizacja bez rozwoju projektu jest długiem na kilka lat. Dlatego dla każdej rodziny zaczynamy od stanu projektu, a dopiero potem od architektury. Niczego nie rekomendujemy: strona ma pokazać, jak te systemy podchodzą do tego samego problemu co klaster Hyper-V i Proxmox VE.

## Jak to działa

<details id="bkmrk-%F0%9F%94%8D-rozwi%C5%84%3A-jak-to-dzi"><summary>🔍 Rozwiń: jak to działa pod spodem</summary>

Każdy hypervisor z wysoką dostępnością składa się z tych samych czterech części. Potrzebujemy elementu, który wie, gdzie co działa, hostów, na których maszyny pracują, magazynu widocznego dla wszystkich hostów i mechanizmu, który po awarii pewnie odcina host, zanim ktoś inny uruchomi jego maszyny.

<div class="callout info">**Pojęcie: hypervisor.** Oprogramowanie, które uruchamia na jednym serwerze wiele maszyn wirtualnych i dzieli między nie procesor, pamięć i dysk. Hyper-V, <abbr title="Keyboard, Video, Mouse: konsola albo przełącznik, który daje jedną klawiaturę, ekran i mysz do wielu serwerów (w Linuksie KVM to też technika wirtualizacji)">KVM</abbr> i Xen to hypervisory, a oVirt, OLVM i Xen Orchestra to narzędzia, którymi nimi zarządzamy.

</div><div class="callout info">**Pojęcie: silnik zarządzania.** Program, który trzyma spis hostów, maszyn i magazynów oraz wydaje polecenia: uruchom, przenieś, zrestartuj po awarii. W klastrze Hyper-V jego rolę pełni sam klaster, w oVirt osobna aplikacja (Engine), a w XCP-ng jeden z hostów puli (master).

</div><div class="callout info">**Pojęcie: fencing.** Pewne odcięcie hosta, o którym nie wiemy, że jest martwy, zanim jego maszyny wystartują gdzie indziej. Gdyby host żył i dalej zapisywał na dysk, a drugi uruchomił tę samą maszynę, dane byłyby uszkodzone. Szerzej o tym mówi strona [Wysoka dostępność: pojęcia, liczenie dostępności i poziomy rezerwy](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/wysoka-dostepnosc-pojecia-liczenie-dostepnosci-i-poziomy-rezerwy).

</div>### Punkt odniesienia: VMware vSphere HA

Jako punkt odniesienia, bez oceny i bez rekomendacji, bierzemy vSphere HA, bo wiele pojęć z dalszych sekcji ma tam odpowiedniki. Hosty <abbr title="hypervisor firmy VMware instalowany na serwerze, na którym działają maszyny wirtualne zarządzane z vCenter">ESXi</abbr> tworzą klaster, w którym jeden host jest głównym (primary), a pozostałe pomocniczymi, a host główny sprawdza pozostałe przez heartbeaty sieciowe wymieniane co sekundę i pingi <abbr title="Internet Control Message Protocol: protokół diagnostyczny sieci, którym działa między innymi ping">ICMP</abbr> na adres zarządzania \[21\]. Gdy host milczy w sieci, ale dalej aktualizuje heartbeat na datastore, jest uznany za odizolowany albo odcięty od hosta głównego, a nie za martwy, więc jego maszyny nie startują drugi raz \[21\]. HA wymaga co najmniej dwóch hostów, wspólnego magazynu i licencji na funkcję, a vSphere 8 ma koniec ogólnego wsparcia 11 października 2027, przy czym dostawca kieruje klientów do pakietów VMware Cloud Foundation (<abbr title="VMware Cloud Foundation: pakiet Broadcom, który łączy vSphere z magazynem, siecią i zarządzaniem w którym Broadcom sprzedaje dziś licencje vSphere">VCF</abbr>) 9.x \[21\].

### oVirt

<div class="callout info">**Pojęcie: oVirt.** Otwarty system zarządzania maszynami wirtualnymi na KVM, który założył Red Hat jako projekt społeczności. Red Hat Virtualization (RHV) był jego komercyjną odmianą \[6\]. Red Hat przeniósł RHV w tryb utrzymaniowy i przestał wnosić wkład do oVirt, więc od tamtej pory projekt trzyma społeczność \[4\].

</div>#### Stan projektu w październiku 2026

Wersja 4.5.7 została ogłoszona jako ogólnie dostępna 13 stycznia 2026, po około dwóch latach bez nowego wydania \[2\]\[4\]. Obsługuje silnik i hosty na CentOS Stream 9 i 10 oraz <abbr title="Red Hat Enterprise Linux: komercyjna dystrybucja Linuksa">RHEL</abbr> 9 i 10 z pochodnymi (AlmaLinux 10), dodała systemy Windows 2025 i RHEL 10 do listy gości i nowy poziom klastra 4.8 \[1\]. Na CentOS Stream 10 wypadły Ceph, Cinderlib i collectd, a obrazy oVirt Node NG są wycofywane na rzecz innych sposobów wdrożenia \[1\]\[2\].

We wrześniu 2025 zespół, który przejął rozwój, opisał naprawę <abbr title="Continuous Integration: automatyczne budowanie i testowanie kodu po każdej zmianie; w ITIL także configuration item, czyli element konfiguracji: każdy składnik usługi zapisany w CMDB">CI</abbr>, przejście na Javę 21 i budowanie na CentOS Stream 10 \[3\]. Mimo to aktywność jest mała. Na liście użytkowników w czerwcu 2026 były trzy wątki, we wrześniu jeden (pytanie o przyszłe wersje z 2 października), a lista deweloperów w sierpniu 2026 nie miała żadnego wątku \[5\]. Nowszego wydania niż 4.5.7 na stronie wydań nie znaleźliśmy, a pytań o następną wersję na liście użytkowników (czerwiec i październik 2026) nie rozstrzygnęliśmy, bo nie przeczytaliśmy odpowiedzi \[5\].

Nasza ocena: oVirt jest aktywny w sensie wydań raz na dwa lata i opieki społeczności, a nie w sensie comiesięcznych poprawek. Historii zmian w repozytorium na GitHubie nie mogliśmy odczytać w tej sesji, więc sprawdzamy ją przed jakąkolwiek decyzją.

#### Architektura

Silnik oVirt (Engine) to aplikacja Java na serwerze WildFly z bazą PostgreSQL, a na każdym hoście KVM działa demon <abbr title="Virtual Desktop and Server Manager: agent na każdym hoście KVM w oVirt i OLVM, który wykonuje polecenia silnika, takie jak uruchom maszynę albo podłącz magazyn">VDSM</abbr>, który wykonuje jego polecenia \[6\]\[10\]. Hosty zgrupowane są w klastry i centra danych, a magazyn to domeny magazynu: <abbr title="Network File System: udostępnianie katalogów po sieci w świecie Linuksa">NFS</abbr> (wersje 3 i 4), <abbr title="Internet Small Computer System Interface: sposób udostępniania dysku z macierzy po zwykłej sieci IP, tak że serwer widzi go jak własny dysk">iSCSI</abbr>, Fibre Channel, systemy plików zgodne z <abbr title="Portable Operating System Interface: wspólny zestaw zasad, dzięki któremu polecenie działa tak samo na różnych Uniksach">POSIX</abbr> (<abbr title="Global File System 2: klastrowy system plików Linuksa, który kilka serwerów montuje naraz na tym samym dysku">GFS2</abbr>), magazyn lokalny i hiperkonwergentny z Gluster \[7\]. W zalecanym układzie silnik działa jako maszyna na samych hostach (self-hosted engine) i jest wysoko dostępny, a dokumentacja wymaga co najmniej dwóch takich hostów \[7\].

[![Rysunek 1. Architektura oVirt, OLVM i XCP-ng. W oVirt silnik zarządza hostami z agentami VDSM, wspólną domeną magazynu i kartami BMC do fencingu. W XCP-ng pula ma jednego mastera z XAPI, hosty wymieniają heartbeat po sieci i przez osobne repozytorium SR, a Xen Orchestra jest opcjonalną nakładką.](https://wiedza.konio-dc.eu/uploads/images/gallery/2026-10/wd-hypervisory-architektura.png)](https://wiedza.konio-dc.eu/uploads/images/gallery/2026-10/wd-hypervisory-architektura.png)

*🔎 Rysunek 1. Architektura oVirt, OLVM i XCP-ng. W oVirt silnik zarządza hostami z agentami VDSM, wspólną domeną magazynu i kartami <abbr title="Baseboard Management Controller: osobny malutki komputer na płycie serwera, który działa nawet przy wyłączonym serwerze i odczytuje m.in. temperatury czujników">BMC</abbr> do fencingu. W XCP-ng pula ma jednego mastera z XAPI, hosty wymieniają heartbeat po sieci i przez osobne repozytorium SR, a Xen Orchestra jest opcjonalną nakładką. (kliknięcie otwiera pełny rozmiar)*

HA maszyny włączamy na jej właściwościach (pole Highly Available), a silnik po awarii hosta uruchamia ją na innym hoście klastra \[8\]\[9\]. Wymaga to skonfigurowanego zarządzania zasilaniem (power management) hostów, czyli dostępu do ich kart BMC, a odcięcia wykonuje inny host jako pośrednik, więc w klastrze lub centrum danych potrzebujemy co najmniej dwóch hostów w stanie Up albo Maintenance \[8\]. Silnik musi mieć pewność, że maszyna nigdzie nie działa, dlatego oVirt zna też dzierżawę maszyny (<abbr title="Virtual Machine: maszyna wirtualna">VM</abbr> lease) na domenie magazynu, która pozwala uruchomić ją na innym hoście nawet po utracie zasilania przez pierwszy i chroni przed dwiema instancjami naraz \[9\]. Migracja na żywo działa przy pracach planowych, a przy awarii hosta maszyna startuje od nowa \[8\]\[13\].

[![Rysunek 2. Przebieg awarii hosta z maszyną wysoko dostępną w oVirt i OLVM, w XCP-ng z włączonym HA oraz we vSphere HA jako punkcie odniesienia. Różnica leży w tym, kto podejmuje decyzję: silnik, sam host albo host główny.](https://wiedza.konio-dc.eu/uploads/images/gallery/2026-10/wd-hypervisory-awaria.png)](https://wiedza.konio-dc.eu/uploads/images/gallery/2026-10/wd-hypervisory-awaria.png)

*🔎 Rysunek 2. Przebieg awarii hosta z maszyną wysoko dostępną w oVirt i OLVM, w XCP-ng z włączonym HA oraz we vSphere HA jako punkcie odniesienia. Różnica leży w tym, kto podejmuje decyzję: silnik, sam host albo host główny. (kliknięcie otwiera pełny rozmiar)*

#### Minimum, kopie i pułapki

Minimum to dwa hosty, wspólny magazyn spoza hostów i dostęp do kart BMC; w zwykłej pracy nie ma tu głosowania hostów jak w klastrze Windows, bo decyduje silnik. Przy dwóch hostach awaria jednego zostawia drugiemu cały ruch, więc podczas prac planowych na drugim hoście nie mamy żadnej rezerwy. Kopie maszyn robimy migawkami i narzędziami do kopii, a silnik zabezpieczamy osobno: poradnik Oracle pokazuje ręczną kopię dysku maszyny silnika w trybie globalnej konserwacji, a upstream ma narzędzie `engine-backup`, którego opcje sprawdzamy w dokumentacji \[14\].

### Oracle Linux Virtualization Manager (OLVM)

<div class="callout info">**Pojęcie: OLVM.** Komercyjnie wspierana odmiana oVirt od Oracle, oparta na tym samym silniku i agencie VDSM, ale z własnymi pakietami i hostami wyłącznie na Oracle Linux \[10\]. Wsparcie jest częścią subskrypcji Oracle Linux Premier Support, a według karty produktu z 2024 roku obejmuje KVM i OLVM, bez dopłaty za hosta KVM i gości Oracle Linux \[13\]. Terminy końca wsparcia dla wydania 4.5 podajemy jako do potwierdzenia w polityce Oracle.

</div>#### Stan i wersje

Dokumentacja wydania 4.5 jest utrzymywana na bieżąco: Informacje o wydaniu mają oznaczenie z sierpnia 2026 \[10\]. Oracle 10 lutego 2026 dodał obsługę hostów KVM z Oracle Linux 9 (co najmniej 9.6, jądro <abbr title="Unbreakable Enterprise Kernel: jądro Linuksa dostarczane przez Oracle w Oracle Linux, osobne od jądra z Red Hat">UEK</abbr> 8 oparte na Linuksie 6.12) oraz obraz silnika wbudowanego na Oracle Linux 9, z zachowaniem migracji na żywo, migawek i HA \[11\]. Hosty Oracle Linux 8 wymagają wydania 8.8 lub nowszego, a wszystkie hosty w środowisku muszą mieć to samo wydanie systemu, żeby HA działało \[12\]. Na jakiej wersji oVirt jest dziś oparty OLVM 4.5, nie ustaliliśmy: w sierpniu 2024 było to 4.5.5 \[11\].

#### Architektura i HA

Architektura jest taka jak w oVirt, więc korzystamy z rysunku 1: silnik na WildFly, agent VDSM na hostach KVM, centrum danych, klastry i domeny magazynu \[10\]. Magazyny to lokalny, NFS, iSCSI i Fibre Channel, a GlusterFS jest dostępny tylko na hostach Oracle Linux 8 i w układzie replica 3 \[12\]. Dokumentacja Oracle opisuje HA tak samo jak upstream: maszyna wysoko dostępna startuje na innym hoście po awarii, ale ręcznie wyłączony host nie przenosi jej sam, a zarządzanie zasilaniem wymaga co najmniej dwóch hostów KVM w stanie Up albo Maintenance \[8\]. Dochodzą dwa scenariusze odtwarzania po katastrofie, aktywny-aktywny i aktywny-pasywny, opisane w podręczniku administratora \[10\].

#### Minimum i pułapki

Minimum to dwa hosty KVM dla silnika wbudowanego \[12\]. Pułapki to wspólne wydanie systemu na wszystkich hostach, brak Glustera poza Oracle Linux 8 i to, że hosty OLVM działają na Oracle Linux, więc nasze serwery z Rocky Linux nie wchodzą w grę. Na czas kopii dysku silnika włączamy tryb globalnej konserwacji, który wstrzymuje automatyczne przenoszenie silnika \[14\].

### XCP-ng z Xen Orchestra i XOSTOR

<div class="callout info">**Pojęcie: XCP-ng.** Otwarta platforma wirtualizacji na hypervisorze Xen, rozwijana przy wsparciu firmy Vates. Hosty tworzą pulę, w której jeden host to master z interfejsem XAPI, a klienci łączą się właśnie z nim \[15\].

</div>#### Stan projektu w październiku 2026

XCP-ng 8.3 wyszedł 7 października 2024, a status wydania z długim wsparciem (LTS) dostał 16 czerwca 2025 i ma wsparcie do 30 listopada 2028 \[15\]. Wydanie 8.2 LTS skończyło życie 16 września 2025 \[15\]. Dokumentacja wymienia Xen 4.17.5, jądro 4.19 w dom0 i bazę CentOS 7 z łatkami bezpieczeństwa przenoszonymi przez zespół, a o XCP-ng 9.0 mówi tylko jako o możliwym przyszłym wydaniu bez terminów \[15\]. Dokumentacja Vates pokazuje aktualizację z 2 sierpnia 2026 \[19\].

Dodatki: Xen Orchestra to interfejs webowy i narzędzie do kopii, XO Lite to lekka konsola jednej puli, a XOSTOR to magazyn hiperkonwergentny z lokalnych dysków hostów \[19\]. Licencje istnieją dwojakie: XCP-ng i Xen Orchestra ze źródeł są otwarte, a firma Vates sprzedaje subskrypcje (Essential, Essential+, Pro i Enterprise) z wsparciem i urządzeniem wirtualnym Xen Orchestra (<abbr title="Xen Orchestra Appliance: gotowa maszyna wirtualna z Xen Orchestra, z którą Vates sprzedaje wsparcie i dodatkowe funkcje">XOA</abbr>), przy czym profesjonalne wsparcie jest dostępne tylko z XOA \[19\]. Szczegółów licencji i cen nie podajemy.

#### Architektura

Pula nie wymaga osobnego serwera zarządzania: klienci łączą się z masterem przez XAPI, a Xen Orchestra jest opcjonalną nakładką \[15\]\[19\]. Po utracie mastera inny host przejmuje jego rolę automatycznie \[16\]. Maszyny z HA muszą leżeć na magazynie współdzielonym (NFS, iSCSI, Fibre Channel albo XOSTOR) i dać się migrować na żywo, a do heartbeatu potrzebne jest osobne repozytorium SR o rozmiarze co najmniej 4 <abbr title="gibibajt: 1024 MiB, czyli około 1,07 GB; tej jednostki używa dokumentacja MailCow przy wymaganiach pamięci">GiB</abbr>, przy czym <abbr title="Server Message Block: protokół udostępniania plików i drukarek w sieci Windows, na nim stoi zwykły udział sieciowy">SMB</abbr> i iSCSI z uwierzytelnianiem <abbr title="Challenge-Handshake Authentication Protocol: uwierzytelnianie hasłem przy połączeniach iSCSI; XCP-ng nie pozwala użyć takiego magazynu na heartbeat HA">CHAP</abbr> nie nadają się na heartbeat \[16\].

Hosty wymieniają dwa rodzaje heartbeatu: pakiety <abbr title="User Datagram Protocol: szybki protokół sieciowy bez potwierdzeń">UDP</abbr> przez interfejs zarządzania i zapisy do pliku stanu (`ha-statefile`) w repozytorium heartbeatu \[16\]. Host, który nie odzyskuje sieci albo magazynu w wyznaczonym czasie (domyślnie 60 sekund), sam się restartuje twardym wyłączeniem, a to jest jego fencing \[16\]. Pula liczy, ile awarii hostów zniesie, i dla każdej maszyny ma priorytet restartu: `restart`, `best-effort` albo `disabled` \[16\]. Migracja na żywo służy do opróżniania hosta przed pracami (`xe host-evacuate`) \[18\].

<div class="callout info">**Pojęcie: XOSTOR.** Sterownik magazynu stworzony przez Vates, który łączy lokalne dyski hostów w jeden magazyn z replikacją przez <abbr title="program do zarządzania replikowanymi woluminami DRBD na wielu serwerach, na którym stoi XOSTOR">LINSTOR</abbr> i <abbr title="Distributed Replicated Block Device: replikowane urządzenie blokowe w jądrze Linuksa, w którym każdy zapis trafia na dwa węzły">DRBD</abbr> \[17\]. Wymaga co najmniej trzech hostów, bo DRBD potrzebuje kworum, pula może mieć najwyżej siedem hostów, a liczba kopii (1, 2 albo 3) jest ustalana przy tworzeniu i nie można jej zmienić \[17\]. Dokumentacja traktuje XOSTOR jako gotowy do produkcji i dodaje, że przed aktualizacją wersji trzeba wyłączyć HA w puli \[17\].

</div>#### Minimum, kopie i pułapki

Dokumentacja mówi, że HA da się uruchomić na dwóch hostach, ale zdecydowanie zaleca trzy, ze względu na ryzyko split brain \[16\]. Przed każdą aktualizacją i restartem host przechodzi w tryb konserwacji \[16\]. Kopie robi Xen Orchestra: migawki rotacyjne, pełne kopie, kopie przyrostowe, replikację pełną i przyrostową, kopie lustrzane repozytorium oraz kopię metadanych puli i konfiguracji XO \[20\]. Które z tych typów wymagają płatnej edycji, dokumentacja nie mówi wprost, więc sprawdzamy to przed zakupem.

</details>## Zestawienie z Hyper-V i Proxmox VE

Tabele mają te same wiersze i dzielimy je na dwie połowy, bo jedenaście kolumn nie mieści się na ekranie. Dla Hyper-V i Proxmox VE bierzemy dane z naszych stron i z dokumentacji producentów, a vSphere zostaje poza tabelą, bo opisaliśmy go wyżej tylko jako punkt odniesienia. Czasy to rzędy wielkości z dokumentacji, a nie wyniki naszych testów.

### Stan, zarządzanie i magazyn

<table id="bkmrk-systemstan-w-pa%C5%BAdzie"><thead><tr><th>System</th><th>Stan w październiku 2026</th><th>Silnik zarządzania</th><th>Magazyn współdzielony</th><th>Migracja na żywo</th></tr></thead><tbody><tr><td>Hyper-V z klastrem (Zielona)</td><td>Windows Server 2022 w Zielonej, rozwijany przez Microsoft</td><td>sam klaster pracy awaryjnej, konsola i PowerShell, bez osobnego serwera</td><td>S2D (`hv01`, `hv02`), CSV</td><td>tak</td></tr><tr><td>Proxmox VE</td><td>wersja 9.2 z 21 maja 2026, Debian 13 \[22\]</td><td>brak osobnego serwera, każdy węzeł ma interfejs, stan trzyma klaster Corosync</td><td>Ceph, NFS, iSCSI, ZFS z replikacją, szczegóły w książce</td><td>tak</td></tr><tr><td>oVirt</td><td>4.5.7 z 13 stycznia 2026, rozwój przez społeczność, mała aktywność \[1\]\[5\]</td><td>Engine (Java, WildFly, PostgreSQL), często jako maszyna na hostach</td><td>NFS, iSCSI, FC, POSIX, Gluster \[7\]</td><td>tak</td></tr><tr><td>OLVM</td><td>wydanie 4.5, dokumentacja z sierpnia 2026, hosty Oracle Linux 8 i 9 \[10\]\[11\]</td><td>Engine jak w oVirt, wsparcie Oracle</td><td>lokalny, NFS, iSCSI, FC, Gluster tylko na OL8 \[12\]</td><td>tak \[13\]</td></tr><tr><td>XCP-ng</td><td>8.3 LTS do 30 listopada 2028 \[15\]</td><td>master puli z XAPI, Xen Orchestra opcjonalnie</td><td>NFS, iSCSI, FC, XOSTOR \[16\]\[17\]</td><td>tak \[18\]</td></tr></tbody></table>

### HA, czasy, kopie i pułapki

<table id="bkmrk-systemminimum-host%C3%B3w"><thead><tr><th>System</th><th>Minimum hostów</th><th>HA i fencing</th><th>Czas po awarii hosta</th><th>Kopie wbudowane</th><th>Typowa pułapka</th></tr></thead><tbody><tr><td>Hyper-V z klastrem (Zielona)</td><td>dwa i świadek poza klastrem</td><td>maszyna jako rola klastra, bez osobnego fencingu: decyduje kworum klastra</td><td>wykrycie po 10 sekundach przy domyślnych ustawieniach \[23\], potem rozruch maszyny: minuty</td><td>Hyper-V Replica (DR), punkty kontrolne</td><td>świadek na maszynie z tego samego klastra</td></tr><tr><td>Proxmox VE</td><td>trzy, albo dwa z urządzeniem QDevice \[22\]</td><td>menedżer HA, host sam się restartuje przez watchdog po 60 sekundach \[22\]</td><td>około 2 minut według dokumentacji \[22\]</td><td>zadania kopii i Proxmox Backup Server</td><td>dwa węzły bez trzeciego głosu</td></tr><tr><td>oVirt</td><td>dwa, plus magazyn i dostęp do BMC \[7\]\[8\]</td><td>HA maszyny przez silnik, power management i dzierżawa maszyny \[8\]\[9\]</td><td>do zmierzenia, minuty: wykrycie, odcięcie, start</td><td>migawki, `engine-backup` dla silnika, odtwarzanie po katastrofie opisuje Oracle \[10\]</td><td>silnik poza układem wysoko dostępnym albo brak dostępu do BMC</td></tr><tr><td>OLVM</td><td>dwa \[12\]</td><td>jak oVirt, wspólne wydanie systemu na hostach \[12\]</td><td>jak oVirt</td><td>jak oVirt</td><td>różne wydania systemu na hostach, brak Glustera poza OL8</td></tr><tr><td>XCP-ng</td><td>dwa, zalecane trzy, XOSTOR trzy \[16\]\[17\]</td><td>HA puli, heartbeat sieci i SR, samodzielny restart hosta (domyślnie 60 s) \[16\]</td><td>limit 60 sekund plus start maszyn</td><td>Xen Orchestra: migawki, kopie, replikacja \[20\]</td><td>HA na lokalnym SR, dwa hosty bez trzeciego</td></tr></tbody></table>

<p class="callout success">Tabela nie jest rankingiem. Hyper-V jest wyborem Zielonej z powodu istniejących licencji i wiedzy zespołu, a przy zmianie hypervisora liczymy nie tylko HA, ale też migrację maszyn, kopie zapasowe i szkolenie dwóch administratorów.</p>

## Częste błędy

<table id="bkmrk-b%C5%82%C4%85dskutekjak-unikam"><thead><tr><th>Błąd</th><th>Skutek</th><th>Jak unikamy</th></tr></thead><tbody><tr><td>Wybór oVirt jako długoterminowego hypervisora bez sprawdzenia aktywności projektu</td><td>jedno wydanie na dwa lata i mała liczba wątków, poprawki mogą przychodzić powoli</td><td>sprawdzamy repozytorium, listy i terminy wsparcia producenta przed decyzją, a przy potrzebie umowy wsparcia bierzemy OLVM</td></tr><tr><td>HA maszyny w oVirt bez skonfigurowanych kart BMC</td><td>silnik nie może pewnie odciąć hosta, więc maszyna nie startuje na drugim</td><td>power management na każdym hoście, test odcięcia, a dla maszyn ważnych dzierżawa na domenie magazynu \[8\]\[9\]</td></tr><tr><td>Silnik oVirt na jednej maszynie poza hostami</td><td>awaria tej maszyny zatrzymuje HA i zarządzanie, choć maszyny dalej pracują</td><td>silnik wbudowany (self-hosted engine) na co najmniej dwóch hostach \[7\]</td></tr><tr><td>Hosty OLVM na różnych wydaniach Oracle Linux</td><td>HA nie działa, bo silnik nie przeniesie maszyny na inne wydanie \[12\]</td><td>jedno wydanie systemu na wszystkich hostach</td></tr><tr><td>Pula XCP-ng z dwoma hostami i włączonym HA</td><td>split brain przy awarii sieci, o którym ostrzega dokumentacja \[16\]</td><td>trzy hosty albo świadome przyjęcie ryzyka</td></tr><tr><td>Maszyny HA w XCP-ng na lokalnym magazynie hosta</td><td>po awarii nie ma skąd ich uruchomić na drugim hoście \[16\]</td><td>współdzielony SR (NFS, iSCSI, FC, XOSTOR)</td></tr><tr><td>XOSTOR z liczbą kopii wybraną na oko</td><td>zmiany nie da się cofnąć po utworzeniu \[17\]</td><td>decyzja o liczbie kopii przed utworzeniem, trzy hosty minimum</td></tr><tr><td>Aktualizacja XCP-ng z HA włączonym i restart hosta bez trybu konserwacji</td><td>host wyłączany bez opróżnienia, możliwe samodzielne restarty innych</td><td>zawsze tryb konserwacji przed pracami \[16\], przed aktualizacją XOSTOR HA wyłączone \[17\]</td></tr><tr><td>Brak kopii samego silnika zarządzania</td><td>po jego utracie odbudowa środowiska trwa dniami</td><td>kopia konfiguracji (Xen Orchestra: metadane \[20\], oVirt: `engine-backup`) obok kopii maszyn</td></tr></tbody></table>

## 🎯 Ćwiczenia

1. Dlaczego oVirt dla maszyny wysoko dostępnej potrzebuje kart BMC albo dzierżawy na magazynie, a XCP-ng nie potrzebuje żadnego z nich?

<details id="bkmrk-odpowied%C5%BA-w-ovirt-de"><summary>Odpowiedź</summary>

W oVirt decyzję podejmuje silnik na zewnątrz hosta, więc musi mieć pewność, że host nie pisze już na dysk, i zdobywa ją odcięciem zasilania przez BMC albo dzierżawą maszyny na magazynie. W XCP-ng decyzję o odcięciu podejmuje sam host: gdy przez 60 sekund (domyślnie) nie ma sieci albo magazynu, restartuje się twardo, więc pula wie, że jego maszyny nie zapisują.

</details>1. Pula XCP-ng ma dwa hosty i włączone HA. Co mówi dokumentacja i co robimy?

<details id="bkmrk-odpowied%C5%BA-dokumentac"><summary>Odpowiedź</summary>

Dokumentacja dopuszcza HA na dwóch hostach, ale zdecydowanie zaleca trzy, żeby uniknąć split brain. Gdy trzeciego hosta nie mamy, świadomie akceptujemy ryzyko, testujemy awarię sieci i przy pracach planowych pamiętamy, że po wyłączeniu jednego hosta nie ma już rezerwy.

</details>1. W OLVM jeden z trzech hostów działa na Oracle Linux 8.8, a dwa na 9.6. Czy HA zadziała i co zmieniamy?

<details id="bkmrk-odpowied%C5%BA-dokumentac-1"><summary>Odpowiedź</summary>

Dokumentacja Oracle wymaga tego samego wydania systemu na wszystkich hostach, żeby HA działało, a silnik wbudowany migruje się tylko na host z tym samym wydaniem. Ujednolicamy wszystkie hosty do jednej wersji (8.8 albo nowszej ósemki, albo 9.6 i nowszej) przed poleganiem na HA.

</details>1. Pan Zbigniew pyta, czy oVirt jest „martwy”. Co odpowiadamy na podstawie tej strony?

<details id="bkmrk-odpowied%C5%BA-%C5%BBe-projekt"><summary>Odpowiedź</summary>

Że projekt ma wydanie z 13 stycznia 2026 (4.5.7) i jest prowadzony przez społeczność po odejściu Red Hata, ale aktywność jest mała: jedno wydanie od około dwóch lat i kilka wątków miesięcznie na listach. Nie jest martwy, ale ryzyko długiego wsparcia jest wyższe niż w produkcie z umową producenta, więc przy potrzebie umowy bierzemy pod uwagę OLVM, a decyzję poprzedzamy przeglądem repozytorium.

</details>**Powiązane:** [Wysoka dostępność: pojęcia, liczenie dostępności i poziomy rezerwy](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/wysoka-dostepnosc-pojecia-liczenie-dostepnosci-i-poziomy-rezerwy) · [Replikacja danych między hostami: DRBD, GlusterFS, Ceph, ZFS i replikacja w aplikacji](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/replikacja-danych-miedzy-hostami-drbd-glusterfs-ceph-zfs-i-replikacja-w-aplikacji) · [Wzorce projektowania wysokiej dostępności: jak dobrać sposób do rodzaju usługi](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/wzorce-projektowania-wysokiej-dostepnosci-jak-dobrac-sposob-do-rodzaju-uslugi) · [Klaster Windows dla własnych usług: rola, zasób, zależności, kworum i testy przełączenia](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/klaster-windows-dla-wlasnych-uslug-rola-zasob-zaleznosci-kworum-i-testy-przelaczenia) · [Macierz wysokiej dostępności usług Zielonej: poziom rezerwy każdej usługi, zależności i kolejność prac](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/macierz-wysokiej-dostepnosci-uslug-zielonej-poziom-rezerwy-kazdej-uslugi-zaleznosci-i-kolejnosc-prac) · [Porównanie mechanizmów HA: Windows, Linux i hypervisory](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/porownanie-mechanizmow-ha-windows-linux-i-hypervisory) · [Proxmox VE: klaster trzech węzłów i HA](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/proxmox-ve-klaster-trzech-wezlow-i-ha) · [Proxmox VE a Hyper-V z Failover Cluster: porównanie i przenosiny](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/proxmox-ve-a-hyper-v-z-failover-cluster-porownanie-i-przenosiny) · [Hyper-V na co dzień: przełącznik, maszyny, punkty kontrolne i migracja](https://wiedza.konio-dc.eu/books/hyper-v-i-storage-spaces-direct/page/hyper-v-na-co-dzien-przelacznik-maszyny-punkty-kontrolne-i-migracja)

**Źródła:** (odczyt 3 października 2026)

1. ovirt.org: [oVirt 4.5.7 Release Notes](https://www.ovirt.org/release/4.5.7/), data wydania, obsługiwane systemy, usunięte funkcje
2. blogs.ovirt.org: [oVirt 4.5.7 is now generally available](https://blogs.ovirt.org/2026/01/ovirt-4-5-7-is-now-generally-available/), 20 stycznia 2026
3. blogs.ovirt.org: [oVirt Project Update](https://blogs.ovirt.org/2025/09/ovirt-project-update/), 24 września 2025
4. phoronix.com: [oVirt 4.5.7 Released After Two Years With New OS &amp; CPU Support](https://phoronix.com/news/oVirt-4.5.7)
5. lists.ovirt.org: archiwa [users@ovirt.org, czerwiec 2026](https://lists.ovirt.org/archives/list/users@ovirt.org/2026/6/), [wrzesień 2026](https://lists.ovirt.org/archives/list/users@ovirt.org/2026/9/) i [devel@ovirt.org, sierpień 2026](https://lists.ovirt.org/archives/list/devel@ovirt.org/2026/8/); wątek [Next major release of oVirt](https://lists.ovirt.org/archives/list/users@ovirt.org/thread/KP5FDANTAYUSVKRKXJAMTQLTV5UKIZHY/), odpowiedzi nieprzeczytane
6. en.wikipedia.org: [oVirt](https://en.wikipedia.org/wiki/OVirt), historia, składniki, wersja 4.5.7
7. ovirt.org: [Planning and Prerequisites Guide](https://www.ovirt.org/documentation/planning_and_prerequisites_guide/), minimum dwóch hostów, typy magazynu, fencing
8. docs.oracle.com: [High Availability and Optimization](https://docs.oracle.com/en/virtualization/oracle-linux-virtualization-manager/arch/architecture-ap-ha-optimize.html), HA maszyn, fencing, power management, minimum dwóch hostów
9. ovirt.org: [Highly Available VMs](https://ovirt.org/develop/ha-vms) i [sanlock fencing](https://ovirt.org/develop/release-management/features/storage/sanlock-fencing); docs.redhat.com: [Improving Uptime with Virtual Machine High Availability](https://docs.redhat.com/ko/documentation/red_hat_virtualization/4.2/html/virtual_machine_management_guide/sect-improving_uptime_with_virtual_machine_high_availability), dzierżawa maszyny
10. docs.oracle.com: [OLVM Release Notes, Release 4.5](https://docs.oracle.com/en/virtualization/oracle-linux-virtualization-manager/relnotes/preface.html) (F52195-20, sierpień 2026) i [Architecture and Planning Guide](https://docs.oracle.com/en/virtualization/oracle-linux-virtualization-manager/arch/architecture-arch-engine.html)
11. blogs.oracle.com: [Oracle Virtualization adds support for Oracle Linux 9 compute](https://blogs.oracle.com/virtualization/oracle-virtualization-adds-support-for-oracle-linux-9-compute), 10 lutego 2026, i [OLVM delivers the latest oVirt community update](https://blogs.oracle.com/virtualization/oracle-linux-virtualization-manager-delivers-the-latest-ovirt-community-update-release), 14 sierpnia 2024
12. docs.oracle.com: [Self-Hosted Engine Deployment](https://docs.oracle.com/en/virtualization/oracle-linux-virtualization-manager/getstart/getstarted-hosted-engine-deploy.html) i [Deploy the Self-Hosted Engine](https://docs.oracle.com/en/virtualization/oracle-linux-virtualization-manager/getstart/getstarted-he-deploy-tasks.html)
13. oracle.com: [Oracle Linux KVM and Virtualization Manager, karta produktu](https://oracle.com/webfolder/dms/prod/docs/manager-ds-20240531.pdf), maj 2024
14. blogs.oracle.com: [oVirt OLVM Engine VM Backup](https://blogs.oracle.com/scoter/ovirt-olvm-engine-vm-backup), polecenia `hosted-engine`
15. docs.xcp-ng.org: [Releases](https://docs.xcp-ng.org/releases/) i [XCP-ng 8.3 LTS](https://docs.xcp-ng.org/releases/release-8-3/); xcp-ng.org: [XCP-ng 8.3 is now LTS](https://xcp-ng.org/blog/2025/06/16/xcp-ng-8-3-is-now-lts/)
16. docs.xcp-ng.org: [High Availability](https://docs.xcp-ng.org/management/ha/)
17. docs.xcp-ng.org: [XOSTOR](https://docs.xcp-ng.org/xostor/)
18. docs.xcp-ng.org: [CLI reference](https://docs.xcp-ng.org/appendix/cli_reference/)
19. docs.vates.tech: [Vates VMS](https://docs.vates.tech/) i [VMS bundle overview](https://docs.vates.tech/pricing-licencing/vms-bundle-overview/); docs.xen-orchestra.com: [Support and licensing](https://docs.xen-orchestra.com/support-and-licencing/support)
20. docs.xen-orchestra.com: [Backup overview](https://docs.xen-orchestra.com/backups-and-dr/backup)
21. techdocs.broadcom.com: [Host Failure Types](https://techdocs.broadcom.com/us/en/vmware-cis/vsphere/vsphere/8-0/vsphere-availability/creating-and-using-vsphere-ha-clusters/how-vsphere-ha-works/host-failure-types-and-detection.html) i [vSphere HA Checklist](https://techdocs.broadcom.com/us/en/vmware-cis/vsphere/vsphere/8-0/vsphere-availability/creating-and-using-vsphere-ha-clusters/creating-a-vsphere-ha-cluster/vmware-ha-checklist.html); msspalert.com: [VMware pushes customers to VCF 9.1 ahead of vSphere 8 end of support](https://www.msspalert.com/brief/vmware-pushes-customers-to-vcf-9-1-ahead-of-vsphere-8-end-of-support)
22. pve.proxmox.com: [High Availability](https://pve.proxmox.com/pve-docs/chapter-ha-manager.html), [Cluster Manager](https://pve.proxmox.com/pve-docs/chapter-pvecm.html) i [Roadmap](https://pve.proxmox.com/wiki/Roadmap)
23. learn.microsoft.com: [Tuning failover cluster network thresholds](https://learn.microsoft.com/en-us/troubleshoot/windows-server/high-availability/iaas-sql-failover-cluster-network-thresholds)

# Porównanie mechanizmów HA: Windows, Linux i hypervisory

<span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#475569;color:#fff">🎚️ Poziom: średnio</span><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#0f766e;color:#fff">🧩 Dotyczy: Windows Failover Cluster, Hyper-V Replica, Storage Replica, Pacemaker i <abbr title="usługa komunikacji klastra, która pilnuje członkostwa węzłów i kworum; Proxmox VE i Pacemaker używają jej do sprawdzania, które węzły żyją">Corosync</abbr>, keepalived i <abbr title="High Availability Proxy: program, który rozdziela połączenia między kilka serwerów i omija te, które nie odpowiadają">HAProxy</abbr>, <abbr title="Distributed Replicated Block Device: replikowane urządzenie blokowe w jądrze Linuksa, w którym każdy zapis trafia na dwa węzły">DRBD</abbr>, Ceph, <abbr title="system plików z migawkami i replikacją przyrostową zbudowany w jednym narzędziu z menedżerem wolumenów (dawniej Zettabyte File System)">ZFS</abbr>, Proxmox VE, oVirt i <abbr title="Oracle Linux Virtualization Manager: komercyjnie wspierana odmiana oVirt od Oracle, której hosty działają na Oracle Linux">OLVM</abbr>, XCP-ng, Docker Swarm, k3s, replikacja baz</span><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#7c3aed;color:#fff">⏱️ Czas: ~40 min</span>

*Ta strona zbiera w jednej tabeli wszystkie mechanizmy wysokiej dostępności opisane w książce i mówi, co każdy z nich chroni, ile ma minimum węzłów, jak rozstrzyga spór i gdzie o nim czytamy. Pod tabelą stoi przewodnik „jeśli masz to, wybierz tamto”. Wracamy tu, gdy ktoś pyta, który mechanizm pasuje do konkretnego układu serwerów, i przed wpisem w macierz usług.*

<p class="callout success">Liczby w tabeli to rzędy wielkości z dokumentacji producentów albo z prób w piaskownicy opisanych na stronach książki. Nie są to pomiary Zielonej ani obietnice, a prawdziwy czas przełączenia poznajemy tylko z testu.</p>

<div id="bkmrk-%F0%9F%A7%AD-za%C5%81o%C5%BBenia-scenariu" style="border:1px solid rgba(14,116,144,.45);border-left:6px solid #0e7490;border-radius:10px;padding:12px 18px;margin:18px 0;background:rgba(14,116,144,.07)"><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#0e7490;color:#fff">🧭 ZAŁOŻENIA SCENARIUSZA</span>

porównanie jest ogólne, a Zielona to w nim jedna serwerownia z dwoma hostami `hv01` i `hv02`, trzecim głosem na fizycznym `bkp01` i bez drugiej lokalizacji. Mechanizmy działające między miejscami, jak Hyper-V Replica, zakładają łącze do osobnej lokalizacji, na przykład do Swarzędza: [IPsec site-to-site: Pamiątkowo i Swarzędz między FortiGate a routerem innej firmy](https://wiedza.konio-dc.eu/books/siec-i-vpn/page/ipsec-site-to-site-pamiatkowo-i-swarzedz-miedzy-fortigate-a-routerem-innej-firmy).

</div><details id="bkmrk-%F0%9F%94%A4-skr%C3%B3ty-u%C5%BCyte-na-te"><summary>🔤 Skróty użyte na tej stronie (10)</summary>

<table style="width:100%"><thead><tr><th style="width:18%">Skrót</th><th>Co znaczy</th></tr></thead><tbody><tr><td>**API**</td><td>Application Programming Interface: sposób, w jaki programy rozmawiają ze sobą</td></tr><tr><td>**Corosync**</td><td>usługa komunikacji klastra, która pilnuje członkostwa węzłów i kworum; Proxmox VE i Pacemaker używają jej do sprawdzania, które węzły żyją</td></tr><tr><td>**DRBD**</td><td>Distributed Replicated Block Device: replikowane urządzenie blokowe w jądrze Linuksa, w którym każdy zapis trafia na dwa węzły</td></tr><tr><td>**etcd**</td><td>etc distributed: rozproszony magazyn par klucz-wartość, w którym Kubernetes trzyma cały stan klastra, a zmiany uzgadnia protokołem Raft</td></tr><tr><td>**HAProxy**</td><td>High Availability Proxy: program, który rozdziela połączenia między kilka serwerów i omija te, które nie odpowiadają</td></tr><tr><td>**OLVM**</td><td>Oracle Linux Virtualization Manager: komercyjnie wspierana odmiana oVirt od Oracle, której hosty działają na Oracle Linux</td></tr><tr><td>**QDevice**</td><td>Quorum Device: trzeci głos dla klastra z dwoma węzłami, działający na osobnym hoście; w Proxmox VE i Pacemakerze rozstrzyga remis</td></tr><tr><td>**S2D**</td><td>Storage Spaces Direct: programowa macierz Windows Server z dysków wielu serwerów</td></tr><tr><td>**UPS**</td><td>Uninterruptible Power Supply: zasilacz awaryjny, podtrzymuje zasilanie urządzeń na czas zaniku napięcia z sieci</td></tr><tr><td>**ZFS**</td><td>system plików z migawkami i replikacją przyrostową zbudowany w jednym narzędziu z menedżerem wolumenów (dawniej Zettabyte File System)</td></tr></tbody></table>

</details>## Z życia wzięte

<div id="bkmrk-%F0%9F%93%96-z-%C5%BBycia-wzi%C4%98tewtor" style="border-left:6px solid #b45309;border-radius:10px;padding:14px 18px;margin:18px 0;background:rgba(180,83,9,.07)"><span style="display:inline-block;padding:2px 10px;margin:0 6px 4px 0;border-radius:999px;font-size:12px;font-weight:700;letter-spacing:.02em;background:#b45309;color:#fff">📖 Z ŻYCIA WZIĘTE</span>

Wtorek, 14:05. Pan Zbigniew przychodzi po tygodniu czytania całej książki o wysokiej dostępności i prosi o jedną kartkę: który z tych mechanizmów jest do czego. Tomek wymienia z pamięci cztery nazwy i wszystkie myli, a Ola kreśli na tablicy tabelę z kolumnami „co chroni”, „ile węzłów” i „kto rozstrzyga spór”. Gdy tabela ma szesnaście wierszy, pan Zbigniew mówi, że rozumie już, dlaczego odpowiedź na pytanie „zróbmy klaster” brzmi „jaki”.

</div>Kartka z wtorku jest tą stroną. Nie wybiera za nas, tylko pokazuje, że każdy mechanizm odpowiada na inne pytanie i ma inną cenę.

## Jak czytać tabelę

Mechanizmy łatwo pomylić, bo wszystkie obiecują „drugi serwer przejmie pracę”. Różnią się tym, co chronią: samego hosta, całą maszynę, usługę albo dane. Różnią się też tym, kto po awarii decyduje, że węzeł nie żyje, i czy potrafi go pewnie odciąć.

[![Rysunek 1. Mapa mechanizmów według warstwy, którą chronią. Hypervisory chronią host i maszynę wirtualną, klastry usług i równoważenie chronią usługę, a replikacja chroni dane. Warstwy się nakładają: maszyny z usługą stoją na hypervisorze, a usługa potrzebuje danych.](https://wiedza.konio-dc.eu/uploads/images/gallery/2026-10/wd-mechanizmy-mapa.png)](https://wiedza.konio-dc.eu/uploads/images/gallery/2026-10/wd-mechanizmy-mapa.png)

*🔎 Rysunek 1. Mapa mechanizmów według warstwy, którą chronią. Hypervisory chronią host i maszynę wirtualną, klastry usług i równoważenie chronią usługę, a replikacja chroni dane. Warstwy się nakładają: maszyny z usługą stoją na hypervisorze, a usługa potrzebuje danych. (kliknięcie otwiera pełny rozmiar)*

<div class="callout info" id="bkmrk-poj%C4%99cie%3A-warstwa-och">**Pojęcie: warstwa ochrony.** Część układu, której awarię mechanizm potrafi przeżyć: host, system w maszynie, usługa albo dane. Mechanizm z jednej warstwy nie widzi awarii w innej, na przykład klaster hostów nie wie, że system w maszynie się zawiesił.

</div><div class="callout info" id="bkmrk-poj%C4%99cie%3A-czas-prze%C5%82%C4%85">**Pojęcie: czas przełączenia.** Czas od awarii do pierwszej poprawnej odpowiedzi usługi. Składa się z wykrycia awarii, pewnego odcięcia węzła (fencing) i startu usługi na drugim węźle, a dla maszyn także z rozruchu systemu.

</div><div class="callout info" id="bkmrk-poj%C4%99cie%3A-kworum-i-%C5%9Bw">**Pojęcie: kworum i świadek.** Kworum to zasada większości głosów, a świadek to dodatkowy głos spoza węzłów, który rozstrzyga remis. Szerzej opisuje je strona [Wysoka dostępność: pojęcia, liczenie dostępności i poziomy rezerwy](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/wysoka-dostepnosc-pojecia-liczenie-dostepnosci-i-poziomy-rezerwy).

</div>Tabela ma szesnaście wierszy, więc dzielimy ją na dwie połowy z tymi samymi wierszami. Pierwsza mówi, co mechanizm chroni i ile kosztuje w węzłach, druga, jak rozstrzyga spór i czego potrzebuje do pracy.

## Co chroni, jak szybko i ile węzłów

<table id="bkmrk-mechanizmsystemco-ch"><thead><tr><th>Mechanizm</th><th>System</th><th>Co chroni</th><th>Czas przełączenia (rząd)</th><th>Minimum węzłów</th><th>Gdzie w książce</th></tr></thead><tbody><tr><td>Windows Failover Cluster: maszyna wirtualna</td><td>Windows Server z Hyper-V</td><td>host: maszyna startuje na drugim hoście, wnętrza systemu nie widzi</td><td>planowo migracja na żywo, pauza rzędu sekund; po awarii wykrycie po 10 sekundach przy domyślnych ustawieniach \[1\] i rozruch maszyny: minuty</td><td>dwa hosty i świadek</td><td>[Perforce i Lore w klastrze: cztery drogi, rekomendacja dla Zielonej i test przełączenia](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/perforce-i-lore-w-klastrze-cztery-drogi-rekomendacja-dla-zielonej-i-test-przelaczenia), [Klaster Windows od zera: budowa, sieć, świadek i S2D](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/klaster-windows-od-zera-budowa-siec-swiadek-i-s2d), [Klaster Windows w utrzymaniu: aktualizacje CAU, monitoring i problemy](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/klaster-windows-w-utrzymaniu-aktualizacje-cau-monitoring-i-problemy)</td></tr><tr><td>Windows Failover Cluster: rola z usługą (klaster gościnny)</td><td>Windows Server</td><td>usługę z adresem, nazwą i dyskiem</td><td>sekundy do minuty, połączenia zrywane</td><td>dwie maszyny gościnne na różnych hostach i świadek</td><td>[Klaster Windows dla własnych usług: rola, zasób, zależności, kworum i testy przełączenia](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/klaster-windows-dla-wlasnych-uslug-rola-zasob-zaleznosci-kworum-i-testy-przelaczenia)</td></tr><tr><td>Hyper-V Replica (odtwarzanie po katastrofie)</td><td>Windows Server z Hyper-V</td><td>kopię maszyny na drugim hoście, zwykle w innym miejscu; nie przejmuje pracy sama</td><td>start ręczny: godziny; dane sprzed 30 sekund, 5 lub 15 minut \[2\]</td><td>dwa hosty (źródło i cel)</td><td>[Perforce i Lore: porównanie dróg do wysokiej dostępności na Windowsie](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/perforce-i-lore-porownanie-drog-do-wysokiej-dostepnosci-na-windowsie)</td></tr><tr><td>Storage Replica (odtwarzanie po katastrofie)</td><td>Windows Server</td><td>wolumen: replikacja synchroniczna (do 5 ms) albo asynchroniczna \[2\]</td><td>start ręczny: godziny</td><td>dwa serwery lub dwa klastry</td><td>[Perforce i Lore: porównanie dróg do wysokiej dostępności na Windowsie](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/perforce-i-lore-porownanie-drog-do-wysokiej-dostepnosci-na-windowsie)</td></tr><tr><td>Pacemaker i Corosync</td><td>Linux (Rocky Linux 9)</td><td>usługę i dane na wspólnym dysku</td><td>dziesiątki sekund</td><td>dwa węzły i trzeci głos (qnetd na `bkp01`)</td><td>[Pacemaker na Linuksie: własna usługa z adresem wirtualnym](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/pacemaker-na-linuksie-wlasna-usluga-z-adresem-wirtualnym), [Pacemaker w utrzymaniu: zarządzanie, testy i aktualizacje](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/pacemaker-w-utrzymaniu-zarzadzanie-testy-i-aktualizacje)</td></tr><tr><td>keepalived i HAProxy</td><td>Linux</td><td>usługę bezstanową i adres wirtualny</td><td>sekundy: około 3 sekund po utracie ogłoszeń VRRP i około 9 sekund po trzech porażkach skryptu (piaskownica)</td><td>dwie maszyny równoważące i dwie instancje usługi</td><td>[Równoważenie i adres wirtualny: keepalived i HAProxy na parze lb01 i lb02](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/rownowazenie-i-adres-wirtualny-keepalived-i-haproxy-na-parze-lb01-i-lb02)</td></tr><tr><td>rsync z timerem i keepalived (ciepła rezerwa Dockera)</td><td>Linux z Dockerem</td><td>pliki aplikacji na drugim hoście i adres wirtualny</td><td>minuty; dane sprzed 15 minut</td><td>dwa hosty</td><td>[Przenoszenie kontenerów z docker01 na docker02: zimna i ciepła rezerwa, przełączenie](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/przenoszenie-kontenerow-z-docker01-na-docker02-zimna-i-ciepla-rezerwa-przelaczenie)</td></tr><tr><td>DRBD</td><td>Linux, moduł spoza dystrybucji</td><td>dane na poziomie bloków</td><td>samo nie przełącza: promocja i montowanie ręcznie albo przez Pacemaker</td><td>dwa węzły i trzeci głos</td><td>[Replikacja danych między hostami: DRBD, GlusterFS, Ceph, ZFS i replikacja w aplikacji](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/replikacja-danych-miedzy-hostami-drbd-glusterfs-ceph-zfs-i-replikacja-w-aplikacji)</td></tr><tr><td>Ceph</td><td>Linux</td><td>dane: obiekty, bloki (RBD), pliki (CephFS), samonaprawa</td><td>OSD uznany za niedziałający po około 20 sekundach, usunięty z puli po 10 minutach (ustawienia domyślne) \[3\]</td><td>trzy węzły i trzy monitory</td><td>[Replikacja danych między hostami: DRBD, GlusterFS, Ceph, ZFS i replikacja w aplikacji](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/replikacja-danych-miedzy-hostami-drbd-glusterfs-ceph-zfs-i-replikacja-w-aplikacji), [Proxmox VE: klaster trzech węzłów i HA](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/proxmox-ve-klaster-trzech-wezlow-i-ha)</td></tr><tr><td>ZFS send/receive</td><td>Linux z modułem OpenZFS</td><td>migawki zbioru na drugim hoście</td><td>przełączenie ręczne; dane sprzed minut (częstość migawek)</td><td>dwa hosty</td><td>[Replikacja danych między hostami: DRBD, GlusterFS, Ceph, ZFS i replikacja w aplikacji](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/replikacja-danych-miedzy-hostami-drbd-glusterfs-ceph-zfs-i-replikacja-w-aplikacji), [Przenoszenie kontenerów z docker01 na docker02: zimna i ciepła rezerwa, przełączenie](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/przenoszenie-kontenerow-z-docker01-na-docker02-zimna-i-ciepla-rezerwa-przelaczenie)</td></tr><tr><td>Proxmox VE HA</td><td>Linux (Debian)</td><td>host: maszyny i kontenery startują na innym węźle</td><td>około 2 minut według dokumentacji \[4\]</td><td>trzy węzły albo dwa z urządzeniem QDevice</td><td>[Proxmox VE: klaster trzech węzłów i HA](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/proxmox-ve-klaster-trzech-wezlow-i-ha), [Proxmox VE w utrzymaniu: kopie PBS, aktualizacje, użytkownicy](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/proxmox-ve-w-utrzymaniu-kopie-pbs-aktualizacje-uzytkownicy), [Proxmox VE a Hyper-V z Failover Cluster: porównanie i przenosiny](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/proxmox-ve-a-hyper-v-z-failover-cluster-porownanie-i-przenosiny)</td></tr><tr><td>oVirt i OLVM</td><td>Linux (CentOS Stream, RHEL, Oracle Linux)</td><td>host: silnik uruchamia maszyny wysoko dostępne na innym hoście</td><td>minuty, do zmierzenia: wykrycie, odcięcie, start</td><td>dwa hosty, wspólny magazyn i dostęp do kart BMC \[5\]</td><td>[Inne hypervisory z HA: oVirt, Oracle Linux Virtualization Manager i XCP-ng](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/inne-hypervisory-z-ha-ovirt-oracle-linux-virtualization-manager-i-xcp-ng)</td></tr><tr><td>XCP-ng z HA</td><td>Linux (Xen)</td><td>host: pula uruchamia maszyny HA na innym hoście</td><td>limit 60 sekund (domyślnie) plus start maszyn \[6\]</td><td>dwa hosty, zalecane trzy</td><td>[Inne hypervisory z HA: oVirt, Oracle Linux Virtualization Manager i XCP-ng](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/inne-hypervisory-z-ha-ovirt-oracle-linux-virtualization-manager-i-xcp-ng)</td></tr><tr><td>Docker Swarm</td><td>Linux z Dockerem</td><td>usługi kontenerowe: zadania startują na innych węzłach</td><td>heartbeat dispatchera co 5 sekund \[7\] plus start zadań, do zmierzenia</td><td>trzech menedżerów</td><td>[Docker Swarm: klaster z trzema menedżerami, na którym przenosimy kolorowy nginx](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/docker-swarm-klaster-z-trzema-menedzerami-na-ktorym-przenosimy-kolorowy-nginx)</td></tr><tr><td>k3s (Kubernetes) z etcd</td><td>Linux</td><td>pody i płaszczyznę sterowania</td><td>węzeł `NotReady` po około 40 sekundach, pody odtwarzane po 300 sekundach (ustawienia domyślne)</td><td>trzy serwery z etcd</td><td>[k3s z trzema węzłami serwerowymi: etcd, adres wirtualny API i Longhorn](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/k3s-z-trzema-wezlami-serwerowymi-etcd-adres-wirtualny-api-i-longhorn)</td></tr><tr><td>Replikacja w aplikacji (bazy, standby)</td><td>PostgreSQL, MongoDB, SQL Server, Perforce i inne</td><td>dane i usługę bazy</td><td>awans ręczny: czas decyzji; automat Patroni: domyślnie ttl 30 sekund \[8\]</td><td>dwa węzły i trzeci głos (arbiter, świadek, magazyn uzgadniania)</td><td>[Replikacja danych między hostami: DRBD, GlusterFS, Ceph, ZFS i replikacja w aplikacji](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/replikacja-danych-miedzy-hostami-drbd-glusterfs-ceph-zfs-i-replikacja-w-aplikacji), [Macierz wysokiej dostępności usług Zielonej: poziom rezerwy każdej usługi, zależności i kolejność prac](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/macierz-wysokiej-dostepnosci-uslug-zielonej-poziom-rezerwy-kazdej-uslugi-zaleznosci-i-kolejnosc-prac)</td></tr></tbody></table>

## Jak rozstrzyga spór i czego potrzebuje

<table id="bkmrk-mechanizmkworum-i-%C5%9Bw"><thead><tr><th>Mechanizm</th><th>Kworum i świadek</th><th>Fencing</th><th>Magazyn</th><th>Złożoność</th></tr></thead><tbody><tr><td>Windows Failover Cluster: maszyna wirtualna</td><td>większość głosów, świadek: udział poza klastrem, dysk albo Cloud Witness</td><td>bez osobnego fencingu urządzeniami, decyduje kworum klastra</td><td>S2D i CSV na `hv01` i `hv02`</td><td>niska do średniej</td></tr><tr><td>Windows Failover Cluster: rola z usługą</td><td>świadek klastra gościnnego poza klastrem hostów (`bkp01`)</td><td>rezerwacja dysku klastrowego (wspólny VHD Set)</td><td>wspólny dysk VHD Set na S2D</td><td>wysoka</td></tr><tr><td>Hyper-V Replica</td><td>brak</td><td>brak</td><td>osobny magazyn na każdym hoście</td><td>średnia</td></tr><tr><td>Storage Replica</td><td>poza klastrem rozciągniętym nie dotyczy (sprawdzamy w dokumentacji)</td><td>brak</td><td>wolumeny po obu stronach</td><td>średnia</td></tr><tr><td>Pacemaker i Corosync</td><td>urządzenie kworum na trzecim hoście, algorytm `ffsplit`</td><td>obowiązkowy: `fence_scsi` na wspólnym dysku albo karty BMC; dla maszyn na Hyper-V do potwierdzenia testem</td><td>wspólny dysk (HA-LVM) albo DRBD</td><td>wysoka</td></tr><tr><td>keepalived i HAProxy</td><td>brak: priorytet VRRP, dwa węzły mogą przejściowo trzymać ten sam adres</td><td>brak, zabezpieczeniem są skrypty i decyzja człowieka</td><td>nie dotyczy, usługa bezstanowa</td><td>niska do średniej</td></tr><tr><td>rsync z timerem i keepalived</td><td>brak</td><td>brak, bezpieczniki w skrypcie synchronizacji</td><td>dyski lokalne obu hostów</td><td>niska</td></tr><tr><td>DRBD</td><td>kworum DRBD 9 z bezdyskowym węzłem głosującym (tiebreaker) \[9\]</td><td>potrzebny w klastrze (Pacemaker), samo DRBD nie odcina</td><td>dyski lokalne replikowane po sieci</td><td>wysoka</td></tr><tr><td>Ceph</td><td>większość monitorów</td><td>nie dotyczy: spójność daje protokół magazynu</td><td>dyski OSD, zalecana sieć 10 Gb</td><td>bardzo wysoka</td></tr><tr><td>ZFS send/receive</td><td>brak</td><td>brak</td><td>pule ZFS na obu hostach</td><td>średnia</td></tr><tr><td>Proxmox VE HA</td><td>kworum Corosync, QDevice jako trzeci głos \[4\]</td><td>watchdog: węzeł bez kworum restartuje się po 60 sekundach \[4\]</td><td>Ceph, magazyn współdzielony albo replikacja ZFS</td><td>średnia</td></tr><tr><td>oVirt i OLVM</td><td>w zwykłej pracy decyduje silnik, nie głosowanie hostów</td><td>karty BMC (pośrednikiem jest drugi host) i dzierżawa maszyny na magazynie \[5\]</td><td>NFS, iSCSI, FC, POSIX</td><td>wysoka</td></tr><tr><td>XCP-ng z HA</td><td>heartbeat sieci i repozytorium SR zamiast głosowania</td><td>host sam się restartuje twardo \[6\]</td><td>wspólne SR (NFS, iSCSI, FC) albo XOSTOR</td><td>średnia</td></tr><tr><td>Docker Swarm</td><td>większość menedżerów (Raft), trzech znosi utratę jednego</td><td>brak</td><td>nie rozwiązuje danych, trzeba osobno</td><td>średnia</td></tr><tr><td>k3s (Kubernetes) z etcd</td><td>większość członków etcd, trzech znosi utratę jednego</td><td>brak</td><td>Longhorn (w naszym układzie dwie repliki) albo magazyn zewnętrzny</td><td>wysoka</td></tr><tr><td>Replikacja w aplikacji</td><td>arbiter, świadek albo magazyn uzgadniania przy automatycznym awansie</td><td>zwykle zbędny, zależy od narzędzia</td><td>każdy węzeł ma własne dane</td><td>średnia</td></tr></tbody></table>

Trzy zdania z tabel zasługują na przypomnienie osobno. Wspólny dysk wymaga fencingu, bo węzeł, który się zawiesił, może dalej pisać na dysk. Dwa węzły bez trzeciego głosu nie rozstrzygną sporu. Trzy węzły na dwóch hostach hypervisora nie dają odporności na awarię hosta, bo host z dwoma węzłami zabiera większość głosów.

## Przewodnik: jeśli masz, wybierz

Przewodnik zaczyna od układu, który Zielona ma dziś, a potem idzie do układów, które spotykamy gdzie indziej. Dla każdego podajemy mechanizm domyślny i warunek, przy którym zmieniamy zdanie. Dobór według rodzaju usługi (stanowa, bezstanowa, baza) opisuje strona [Wzorce projektowania wysokiej dostępności: jak dobrać sposób do rodzaju usługi](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/wzorce-projektowania-wysokiej-dostepnosci-jak-dobrac-sposob-do-rodzaju-uslugi), a tu patrzymy od strony sprzętu i systemu.

<table id="bkmrk-je%C5%9Bli-maszwybieramyd"><thead><tr><th>Jeśli masz</th><th>Wybieramy</th><th>Dlaczego i kiedy zmieniamy zdanie</th></tr></thead><tbody><tr><td>Dwa hosty Windows z S2D (`hv01`, `hv02`)</td><td>maszyny jako role klastra Hyper-V i świadek poza klastrem na `bkp01`</td><td>klaster hostów chroni przed awarią sprzętu; gdy przerwa po awarii maszyny za długa dla usługi, dokładamy klaster gościnny z dwóch maszyn (wd2-01)</td></tr><tr><td>Te same dwa hosty i potrzebę kopii w drugim miejscu</td><td>Hyper-V Replica albo Storage Replica do trzeciego miejsca</td><td>to odtwarzanie po katastrofie, a nie HA, i nie zastępuje kopii zapasowej</td></tr><tr><td>Trzy hosty linuksowe i maszyny wirtualne</td><td>Proxmox VE z HA, a Ceph jako magazyn, jeśli sieć i dyski to udźwigną</td><td>trzy węzły dają kworum bez świadka; oVirt albo XCP-ng wybieramy z powodów spoza HA, na przykład wsparcia Oracle albo istniejącej wiedzy</td></tr><tr><td>Trzy hosty linuksowe i same kontenery</td><td>k3s z trzema serwerami na trzech hostach</td><td>trzy serwery na dwóch hostach nie przeżyją awarii hosta; Swarm tylko dla aplikacji bezstanowych, gdy zespół zna Dockera</td></tr><tr><td>Dwa hosty z Dockerem i aplikacje trzymające dane w plikach</td><td>rsync z timerem, restic na `bkp01` i keepalived z adresem wirtualnym</td><td>prosta ciepła rezerwa z danymi sprzed kwadransa; ZFS send/receive, gdy RPO ma spaść do minut</td></tr><tr><td>Jedna usługa stanowa na dwóch węzłach Linuksa</td><td>Pacemaker z trzecim głosem na `bkp01` i fencingiem</td><td>bez fencingu nie wdrażamy; gdy fencingu nie da się zrobić, maszyna jako rola klastra hypervisora jest prostsza</td></tr><tr><td>Usługa bezstanowa (serwer WWW, aplikacje Java za HAProxy)</td><td>keepalived i HAProxy z dwiema instancjami</td><td>niewidoczne wyłączenie jednej instancji, sekundy po awarii; dane trzymamy w bazie</td></tr><tr><td>Baza danych (PostgreSQL, MongoDB, SQL Server)</td><td>replikacja natywna z arbitrem albo świadkiem</td><td>silnik zna potwierdzone zapisy; awans automatyczny (na przykład Patroni) wymaga trzeciego głosu, a ręczny przynajmniej zdecydowanej osoby</td></tr><tr><td>Dane na wspólnym dysku bez klastra usług</td><td>DRBD z tiebreakerem albo ZFS send/receive</td><td>DRBD dla RPO bliskiego zeru i z Pacemakerem do przełączenia, ZFS dla prostszej ciepłej rezerwy</td></tr><tr><td>Potrzebę sekund, a nie minut</td><td>keepalived, replikacja natywna baz, klaster usług</td><td>restart maszyny po awarii hosta to minuty; sekundy daje tylko mechanizm wyżej niż hypervisor</td></tr><tr><td>Druga lokalizacja i brak potrzeby automatu</td><td>Hyper-V Replica, ZFS send/receive albo replikacja asynchroniczna bazy</td><td>start repliki wykonuje człowiek; ustalamy, kto i kiedy</td></tr></tbody></table>

Przewodnik nie zastępuje testu. Gdy wybieramy mechanizm, ustalamy też, kto go uruchomi o 20:00 w piątek i kto sprawdzi, że kopia zapasowa dalej istnieje.

## Gdy mechanizmy nakładają się

W Zielonej prawie każda usługa stoi w warstwach, więc mechanizmy z tabeli działają jednocześnie. Maszyna `pcmk01` jest rolą klastra Hyper-V, a w środku ma Pacemaker. Baza `pg01` ma replikację natywną, a sama stoi na <abbr title="Storage Spaces Direct: programowa macierz Windows Server z dysków wielu serwerów">S2D</abbr>. Dobrze jest wiedzieć, które pary ze sobą współpracują, a które sobie przeszkadzają.

<table id="bkmrk-para-warstwco-si%C4%99-dz"><thead><tr><th>Para warstw</th><th>Co się dzieje</th><th>Co robimy</th></tr></thead><tbody><tr><td>maszyna jako rola klastra Hyper-V i Pacemaker w gościu</td><td>migracja na żywo wstrzymuje maszynę na chwilę, która może przekroczyć limity czasu Corosync</td><td>sprawdzamy na laboratorium; przed pracami na hoście wstrzymujemy węzeł (`pcs node standby`) [Pacemaker na Linuksie: własna usługa z adresem wirtualnym](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/pacemaker-na-linuksie-wlasna-usluga-z-adresem-wirtualnym)</td></tr><tr><td>k3s z trzema węzłami na dwóch hostach Hyper-V</td><td>awaria hosta z dwoma węzłami zabiera kworum etcd do czasu restartu maszyn</td><td>trzeci fizyczny host albo świadome przyjęcie ryzyka [k3s z trzema węzłami serwerowymi: etcd, adres wirtualny API i Longhorn](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/k3s-z-trzema-wezlami-serwerowymi-etcd-adres-wirtualny-api-i-longhorn)</td></tr><tr><td>Longhorn nad S2D</td><td>S2D trzyma już dwie kopie bloków, więc repliki Longhorna mnożą zajętość</td><td>dwie repliki, nie trzy</td></tr><tr><td>replikacja bazy w maszynie klastra</td><td>klaster restartuje maszynę, a replika ma własny awans; dwa mechanizmy mogą się rozmijać</td><td>jeden mechanizm decyduje o awansie, drugi tylko restartuje maszynę, i opisujemy to w macierzy</td></tr><tr><td>klaster hostów i dwa kontrolery domeny na nim</td><td>rezerwa kontrolerów nie chroni przed awarią klastra, który je niesie</td><td>kontrolery na różnych hostach, kopia i awaryjne konto [Macierz wysokiej dostępności usług Zielonej: poziom rezerwy każdej usługi, zależności i kolejność prac](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/macierz-wysokiej-dostepnosci-uslug-zielonej-poziom-rezerwy-kazdej-uslugi-zaleznosci-i-kolejnosc-prac)</td></tr></tbody></table>

## Odniesienie do macierzy wd4-01

Po wyborze mechanizmu zapisujemy go w macierzy [Macierz wysokiej dostępności usług Zielonej: poziom rezerwy każdej usługi, zależności i kolejność prac](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/macierz-wysokiej-dostepnosci-uslug-zielonej-poziom-rezerwy-kazdej-uslugi-zaleznosci-i-kolejnosc-prac), w kolumnie „mechanizm docelowy”. Macierz pamięta poziom rezerwy (zimna, ciepła, gorąca) i to, ile dziś naprawdę mamy, a ta strona dobiera mechanizm do tego poziomu.

Zasada z macierzy obowiązuje bez zmian: poziom usługi nie przekracza poziomu jej najsłabszej zależności i podnosimy go dopiero po teście przełączenia. Gitea z ciepłą rezerwą na `docker02` i bazą na `pg01` bez repliki zostaje w macierzy zimna, bez względu na to, który mechanizm z tabeli wyżej wybraliśmy dla plików.

## Częste błędy

<table id="bkmrk-b%C5%82%C4%85dskutekjak-unikam"><thead><tr><th>Błąd</th><th>Skutek</th><th>Jak unikamy</th></tr></thead><tbody><tr><td>Porównujemy mechanizmy po samym czasie przełączenia</td><td>wybieramy najszybszy, który nie chroni tego, co potrzebujemy</td><td>najpierw warstwa ochrony (host, usługa, dane), potem czas</td></tr><tr><td>Dwa węzły i brak trzeciego głosu w mechanizmie z kworum</td><td>po zerwaniu łączności żaden nie ma większości albo oba uznają się za aktywne</td><td>świadek, qdevice, arbiter albo trzeci węzeł, zależnie od mechanizmu</td></tr><tr><td>Wspólny dysk i klaster usług bez fencingu</td><td>zawieszony węzeł pisze na dysk razem z drugim, a system plików ulega uszkodzeniu</td><td>fencing obowiązkowy albo mechanizm bez wspólnego dysku</td></tr><tr><td>Trzy węzły na dwóch hostach uznane za odporność na awarię hosta</td><td>host z dwoma węzłami zabiera większość głosów</td><td>trzy hosty albo świadome przyjęcie ryzyka</td></tr><tr><td>Odtwarzanie po katastrofie uznane za HA</td><td>replika startuje ręcznie, a dane są sprzed 30 sekund do kwadransa</td><td>w macierzy opisujemy to jako DR i nie obiecujemy nim RTO</td></tr><tr><td>Replika zamiast kopii zapasowej</td><td>skasowanie i ransomware docierają do rezerwy w sekundy</td><td>kopia restic, RMAN albo pgBackRest zostaje obok każdego mechanizmu</td></tr><tr><td>Czas z tabeli wpisany do umowy z właścicielem usługi</td><td>w dniu awarii przerwa jest dłuższa niż obiecana</td><td>wpisujemy czas z naszego testu przełączenia, najgorszy z kilku pomiarów</td></tr><tr><td>Dwa mechanizmy decydują o tym samym zdarzeniu</td><td>klaster hostów restartuje maszynę, a klaster usług w niej przenosi rolę, więc przerwa się mnoży</td><td>opisujemy, kto decyduje, a drugi mechanizm ustawiamy tylko jako zabezpieczenie</td></tr></tbody></table>

## 🎯 Ćwiczenia

1. Dwa hosty Windows z S2D i jedna usługa, której przerwa po awarii hosta nie może przekroczyć minuty. Który mechanizm z tabeli bierzemy najpierw i co dokładamy, gdy minuta nie wystarcza?

<details id="bkmrk-odpowied%C5%BA-najpierw-m"><summary>Odpowiedź</summary>

Najpierw maszyna jako rola klastra Hyper-V ze świadkiem poza klastrem, bo chroni przed awarią hosta i dla maszyny daje migrację na żywo przy pracach planowych. Po awarii hosta maszyna startuje od nowa, co daje minuty, więc gdy minuta nie wystarcza, dokładamy klaster gościnny z dwóch maszyn na różnych hostach, w którym rola przechodzi w sekundach do minuty. Wyboru nie podejmujemy bez zmierzenia przerwy w teście.

</details>1. Dlaczego Hyper-V Replica i Storage Replica stoją w tabeli, choć nie przejmują pracy same?

<details id="bkmrk-odpowied%C5%BA-bo-to-mech"><summary>Odpowiedź</summary>

Bo to mechanizmy odtwarzania po katastrofie z drugiej lokalizacji, a nie wysokiej dostępności. Chronią dane przed utratą miejsca albo hosta, ale start repliki wykonuje człowiek (godziny), a dane są sprzed 30 sekund do 15 minut (Hyper-V Replica) albo bliskie zeru (Storage Replica synchroniczna). Stoją w tabeli, żeby nikt nie wpisał ich do macierzy jako gorącej rezerwy.

</details>1. Mamy trzy hosty linuksowe i chcemy trzech węzłów <abbr title="etc distributed: rozproszony magazyn par klucz-wartość, w którym Kubernetes trzyma cały stan klastra, a zmiany uzgadnia protokołem Raft">etcd</abbr> dla k3s. Jak ułożyć węzły i co zmienia się, gdy hostów są tylko dwa?

<details id="bkmrk-odpowied%C5%BA-po-jednym-"><summary>Odpowiedź</summary>

Po jednym węźle na każdym z trzech hostów, wtedy awaria hosta zostawia dwa głosy z trzech i klaster działa dalej. Przy dwóch hostach jeden z nich trzyma dwa węzły, a jego awaria zabiera większość głosów, więc <abbr title="Application Programming Interface: sposób, w jaki programy rozmawiają ze sobą">API</abbr> przestaje przyjmować zmiany do czasu, aż hypervisor uruchomi maszyny na drugim hoście. Przy dwóch hostach lepiej wybrać prostszy mechanizm, na przykład rsync z keepalived.

</details>1. Dla jakiej pary mechanizmów w tabeli rozstrzygnięcie sporu zależy od tego samego trzeciego elementu, jakim jest `bkp01`?

<details id="bkmrk-odpowied%C5%BA-%C5%9Awiadek-kl"><summary>Odpowiedź</summary>

Świadek klastra Hyper-V (udział na `bkp01`, propozycja z macierzy) i trzeci głos klastra Pacemakera (qnetd na `bkp01`). Obie funkcje może pełnić ten sam fizyczny serwer poza klastrem hostów, więc jego awaria odbiera jednocześnie świadka i trzeci głos, a on sam stoi na tym samym <abbr title="Uninterruptible Power Supply: zasilacz awaryjny, podtrzymuje zasilanie urządzeń na czas zaniku napięcia z sieci">UPS</abbr> co serwery. Dlatego `bkp01` jest w macierzy punktem awarii, który trzeba zabezpieczyć.

</details>**Powiązane:** [Wysoka dostępność: pojęcia, liczenie dostępności i poziomy rezerwy](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/wysoka-dostepnosc-pojecia-liczenie-dostepnosci-i-poziomy-rezerwy) · [Przenoszenie kontenerów z docker01 na docker02: zimna i ciepła rezerwa, przełączenie](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/przenoszenie-kontenerow-z-docker01-na-docker02-zimna-i-ciepla-rezerwa-przelaczenie) · [Replikacja danych między hostami: DRBD, GlusterFS, Ceph, ZFS i replikacja w aplikacji](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/replikacja-danych-miedzy-hostami-drbd-glusterfs-ceph-zfs-i-replikacja-w-aplikacji) · [Wzorce projektowania wysokiej dostępności: jak dobrać sposób do rodzaju usługi](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/wzorce-projektowania-wysokiej-dostepnosci-jak-dobrac-sposob-do-rodzaju-uslugi) · [Klaster Windows dla własnych usług: rola, zasób, zależności, kworum i testy przełączenia](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/klaster-windows-dla-wlasnych-uslug-rola-zasob-zaleznosci-kworum-i-testy-przelaczenia) · [Pacemaker na Linuksie: własna usługa z adresem wirtualnym](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/pacemaker-na-linuksie-wlasna-usluga-z-adresem-wirtualnym) · [Równoważenie i adres wirtualny: keepalived i HAProxy na parze lb01 i lb02](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/rownowazenie-i-adres-wirtualny-keepalived-i-haproxy-na-parze-lb01-i-lb02) · [Docker Swarm: klaster z trzema menedżerami, na którym przenosimy kolorowy nginx](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/docker-swarm-klaster-z-trzema-menedzerami-na-ktorym-przenosimy-kolorowy-nginx) · [k3s z trzema węzłami serwerowymi: etcd, adres wirtualny API i Longhorn](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/k3s-z-trzema-wezlami-serwerowymi-etcd-adres-wirtualny-api-i-longhorn) · [Macierz wysokiej dostępności usług Zielonej: poziom rezerwy każdej usługi, zależności i kolejność prac](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/macierz-wysokiej-dostepnosci-uslug-zielonej-poziom-rezerwy-kazdej-uslugi-zaleznosci-i-kolejnosc-prac) · [Inne hypervisory z HA: oVirt, Oracle Linux Virtualization Manager i XCP-ng](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/inne-hypervisory-z-ha-ovirt-oracle-linux-virtualization-manager-i-xcp-ng) · [Proxmox VE: klaster trzech węzłów i HA](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/proxmox-ve-klaster-trzech-wezlow-i-ha) · [Proxmox VE w utrzymaniu: kopie PBS, aktualizacje, użytkownicy](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/proxmox-ve-w-utrzymaniu-kopie-pbs-aktualizacje-uzytkownicy) · [Proxmox VE a Hyper-V z Failover Cluster: porównanie i przenosiny](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/proxmox-ve-a-hyper-v-z-failover-cluster-porownanie-i-przenosiny) · [Klaster Windows od zera: budowa, sieć, świadek i S2D](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/klaster-windows-od-zera-budowa-siec-swiadek-i-s2d) · [Klaster Windows w utrzymaniu: aktualizacje CAU, monitoring i problemy](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/klaster-windows-w-utrzymaniu-aktualizacje-cau-monitoring-i-problemy) · [Pacemaker w utrzymaniu: zarządzanie, testy i aktualizacje](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/pacemaker-w-utrzymaniu-zarzadzanie-testy-i-aktualizacje)

**Źródła:** (odczyt 3 października 2026)

1. learn.microsoft.com: [Tuning failover cluster network thresholds](https://learn.microsoft.com/en-us/troubleshoot/windows-server/high-availability/iaas-sql-failover-cluster-network-thresholds), domyślnie 1000 ms razy 10 pulsów
2. learn.microsoft.com: [Hyper-V Replica overview](https://learn.microsoft.com/en-us/windows-server/virtualization/hyper-v/replication-overview) i [Storage Replica overview](https://learn.microsoft.com/en-us/windows-server/storage/storage-replica/storage-replica-overview), za [Perforce i Lore: porównanie dróg do wysokiej dostępności na Windowsie](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/perforce-i-lore-porownanie-drog-do-wysokiej-dostepnosci-na-windowsie)
3. docs.ceph.com: [Configuring Monitor/OSD Interaction](https://docs.ceph.com/en/latest/rados/configuration/mon-osd-interaction/), `osd_heartbeat_grace` 20 sekund, `mon_osd_down_out_interval` 10 minut
4. pve.proxmox.com: [High Availability](https://pve.proxmox.com/pve-docs/chapter-ha-manager.html) i [Cluster Manager](https://pve.proxmox.com/pve-docs/chapter-pvecm.html), trzy węzły albo <abbr title="Quorum Device: trzeci głos dla klastra z dwoma węzłami, działający na osobnym hoście; w Proxmox VE i Pacemakerze rozstrzyga remis">QDevice</abbr>, watchdog po 60 sekundach, około 2 minut
5. ovirt.org: [Planning and Prerequisites Guide](https://www.ovirt.org/documentation/planning_and_prerequisites_guide/); docs.oracle.com: [High Availability and Optimization](https://docs.oracle.com/en/virtualization/oracle-linux-virtualization-manager/arch/architecture-ap-ha-optimize.html)
6. docs.xcp-ng.org: [High Availability](https://docs.xcp-ng.org/management/ha/)
7. docs.docker.com: [docker swarm update](https://docs.docker.com/reference/cli/docker/swarm/update/), `--dispatcher-heartbeat` domyślnie 5 sekund
8. patroni.readthedocs.io: [Dynamic configuration settings](https://patroni.readthedocs.io/en/latest/dynamic_configuration.html), `ttl` 30, `loop_wait` 10, `retry_timeout` 10
9. LINBIT: [DRBD 9 User Guide](https://linbit.com/drbd-user-guide/drbd-guide-9_0-en/), za [Replikacja danych między hostami: DRBD, GlusterFS, Ceph, ZFS i replikacja w aplikacji](https://wiedza.konio-dc.eu/books/wysoka-dostepnosc/page/replikacja-danych-miedzy-hostami-drbd-glusterfs-ceph-zfs-i-replikacja-w-aplikacji)
10. Ta baza wiedzy: strony wd1-01 do wd4-01 i wd8-01 z kolumny „Gdzie w książce”, opisy testów i piaskownicy na stronach wd3-01, wd3-02 i wd3-03